2-5 DAYS DELIVERY
Dayton 12.5 water softener easy Programmable
100% ORIGINAL AND QUALITY
- Description
- Shipping information
- Reviews
oftening of next-generation valve volume and easy programming. Dayton delayed regeneration valve 859D to mixing valve to adjust the hardness out. Bypass installation included. Electronic controller integrated into the top cover. Pre-assembled and tested system for a easier installation and start-up. Battery incorporated for dinamic memory. Four different regeneration: Time initiated - Delayed regenerations according to selected frequence (Ex: Softener will regenerate every three days at 02:00AM). Meter immediate - Regenerations are started after treating the programmed volume of water. Delayed regenerations - Regenerations are started after treating the programmed volume of water at the programmed hour. Mixed regeneration - Similar to delayed regeneration, but it allows to program a maximum period of time without regenerations. After this time the system will start a delayed regeneration. CE, NSF, D.M. 25, D.M. 174 Certified.
All devices can be customized with your logo.
Features
* Pressure min.: 2,5 bar(2,5 kg/cm2)
* Pressure Max.: 8 bar(8 kg/cm2)
* Temperature Min: 4°C
* Temperature Max: 35°C
* Inlet/Outlet water 1" M. (30lt.), 3/4" M. (slim 7, slim 12, 12.5, slim 18, 18lt.)
Water hardness (limestone)
In °F (French degrees), can be measured with the drops of Titrant, important to determine the choice of the type of water softener and optimize the consumption of salt.
Ability to interchange
Hardness of the water softener is able to hold.
7 slim resin liters: 22ºHFxm3 * 12 slim resin Liters: 49ºHFxm3 * 12.5 resin Liters: 49ºHFxm3 * 18 slim resin Liters: 97ºHFxm3 * 18 resin Liters: 97ºHFxm3 * 30 resin Liters: 170ºHFxm3.
Sample calculation to determine the correct article
A water softner of 30 liters resin with a hardness of 40°F (medium-high hardness), develops 4.250liters of softened water (170:40 = 4.250). In this case, must planning 4.2m3 in treatment capacity of the softener through the buttons on the display and provides free water softener without scale at zero French degrees.
Adjustment of the hardness out
It's recommended to not leak totally softened water in a residential installation. Dayton Water softeners have a residual hardness integrated regulator that allows you to precisely adjust the hardness of the treated water. To adjust the residual hardness must then carefully open the regulator MIX valve. All softeners are supplied with the valve fully closed and then will deliver water at 0°F. Water intended for human consumption, we recommend a residual hardness between 5 and 10ºF for copper pipes and between 8 and 10 º F for iron pipes. Depending on the hardness out planned, the water softener will tend to produce more water and less sweetened salt intake because the input hardness must be compensated with the output value. A water softner of 30 liter resin with a hardness of incoming 40°F and 5°F and out of hardness, develops 4.857lit. of softened water (170:35=4.857). In this case must planning 4.9 m3 in treatment capacity of the softener through the buttons on the display. The average every person consumes 150 liters of water a day is recommended and a regeneration time scheduled every 4/5 days, then a family of 4 with water at 40°F consumes x5 days 3.000 liters, a 30 liters of water softner so with a planned regeneration even at 6 days can be installed.
Benefits and advantages
Reduction of water hardness, which is cause of scale. ENERGY SAVING: the device prevents the formation of deposits in pipes and hydraulic lines. Greater sense of wellness during the shower. Skin soft and clean. Increased duration of appliances and boilers. COST SAVING: reduction in the use of soaps, fabric softeners and chemicals. Reduced maintenance costs. Fully automatic operation. It should just worry about adding salt in the water softner.
Increased sodium (for drinking water)
Most of the sodium consumed is taken with food, especially those produced by industrial processing. Salt is an excellent preservative and is used as an additive for processed products. The intake of sodium with the water we drink is relatively low compared to that which is taken with food. All softeners to produce soft water using ion exchange resins in the produce softened water output of sodium ions. The recommended sodium limit for water intended for human consumption is 200 liters ppm. Depending on the concentration of sodium and water hardness, the water can have a concentration of sodium than the recommended. Where this occurs, or if you need to follow a diet low in salt, it is advisable to install a reverse osmosis drinking water for the home.
Specifications Model 12,5lt. resin. (ideal for 2/3 people)
* Regeneration salt consumption: 1,00 kg/salt.
* Water consumption for regeneration: 62,5lt.
* Number treated water for regeneration, 35°F-1,400m3, 40°F-1,225m3, 45°F-1,088m3, 50°F-0,980m3, 60°F-0,816m3.
* Working flow 0,5m3/h
* Working flow MAX 0,75m3/h
* Dimensions mm (WxDxH) 300 x 500 x 580
We ship with BRT Express Courier, guaranteeing delivery within 2-5 days throughout Italy.